STORAGE RANGE 60 ÷ 200 kWh – THREE PHASE / 50 Hz

THE TECNOGEN SMART ENERGY STORAGE SYSTEM
WITH LITHIUM BATTERY AND INTEGRATED INVERTER/CHARGER

EXAMPLE OF ELECTRICAL PANEL

KEY FEATURES

■ Up to more than 450% overload capacity for 300 seconds
■ Parallel capability standard
■ Digital control panel
■ Canopy made of galvanized steel
■ Recessed central lifting hook
■ 4 Lifting eyes
■ Forklift guides on every side
■ Two levels stackable
■ EV charger DC CCS2 and AC TYPE2 as option

LiNMC BATTERY CHEMISTRY

ENERMAX-CUMMINS234567

GENERAL TECNICAL DATA

Units

EP 180 / 200 T N

EP 120 / 200 T N

EP 120 / 100 T N

EP 80 / 100 T N

EP 40 / 120 T N

EP 40 / 100 T N

EP 40 / 60 T N

Three phase Voltage

VAC

400

400

400

400

400

400

400

Single phase Voltage

VAC

230

230

230

230

230

230

230

Frequency

Hz

50

50

50

50

50

50

50

Nominal Energy Storage

kWh

224

224

112

112

112

112

74

Continous load at power factor = 0,8

kVA

180

120

120

80

40

50

50

Overload (300 seconds)1

kV

350

350

350

350

350

350

350

Comunication technology

CAN bus

CAN bus

CAN bus

CAN bus

CAN bus

CAN bus

CAN bus

Sound Power Level

dB(A)

< 55 dB(A)@7m

< 55 dB(A)@7m

< 55 dB(A)@7m

< 55 dB(A)@7m

< 55 dB(A)@7m

< 55 dB(A)@7m

< 55 dB(A)@7m

Protection degree

IP44

IP44

IP44

IP44

IP44

IP44

IP44

Phases

3 PHASE

3 PHASE

3 PHASE

3 PHASE

3 PHASE

3 PHASE

3 PHASE

Operation Temperature

°C

-20 °C to +45 °C 2

-20 °C to +45 °C 2

-20 °C to +45 °C 2

-20 °C to +45 °C 2

-20 °C to +45 °C 2

-20 °C to +45 °C 2

-20 °C to +45 °C 2

ENERMAX-CUMMINS750 Ah1100 Ah4567
BATTERY

Unit

EP 180 / 200 T N

EP 120 / 200 T N

EP 120 / 100 T N

EP 80 / 100 T N

EP 40 / 120 T N

EP 40 / 100 T N

EP 40 / 60 T N

Brand

Quantity

units

12

12

6

6

6

6

4

Battery Voltage

VDC

388,8

388,8

388,8

388,8

388,8

388,8

388,8

Operating Voltage

VDC

777,6

777,6

777,6

777,6

777,6

777,6

777,6

Lithium cell chemistry

LiNMC

LiNMC

LiNMC

LiNMC

LiNMC

LiNMC

LiNMC

Discharge current

2 C

2 C

2 C

2 C

2 C

2 C

2 C

DOD % (depth of discharge @25 °C ±3)

80%

80%

80%

80%

80%

80%

80%

Cycle Life3

>6000

>6000

>6000

>6000

>6000

>6000

>6000

Manufacturing Country

ITALY

ITALY

ITALY

ITALY

ITALY

ITALY

ITALY

ENERMAX-CUMMINS234567
INVERTER

Units

EP 180 / 200 T N

EP 120 / 200 T N

EP 120 / 100 T N

EP 80 / 100 T N

EP 40 / 120 T N

EP 40 / 100 T N

EP 40 / 60 T N

Brand

Quantity

units

1

1

1

1

1

1

1

Continuos load at power factor = 0,8

kVA

180

120

120

80

40

40

40

Nominal Power

kW

144

96

96

64

32

32

32

Accepted peak load @ 400V (300 sec)

kW

350 (2,43 Pn)

350 (3,64 Pn)

350 (3,64 Pn)

150 (2,34Pn)

150 (4,68Pn)

150 (4,68Pn)

150 (4,68Pn)

Manufacturing Country

ITALY

ITALY

ITALY

ITALY

ITALY

ITALY

ITALY

ENERMAX-CUMMINS750 Ah1100 Ah4567
CONTROL

Units

EP 180 / 200 T N

EP 120 / 200 T N

EP 120 / 100 T N

EP 80 / 100 T N

EP 40 / 120 T N

EP 40 / 100 T N

EP 40 / 60 T N

Energy Management system (EMS)

ComAp

ComAp

ComAp

ComAp

ComAp

ComAp

ComAp

Battery management system (BMS)

Hermes M3

Hermes M3

Hermes M3

Hermes M3

Hermes M3

Hermes M3

Hermes M3

Brand

Manufacturing Country

ITALY

ITALY

ITALY

ITALY

ITALY

ITALY

ITALY

ENERMAX-CUMMINS750 Ah1100 Ah4567
DIMENSIONS AND WEIGHT

Unit

EP 180 / 200 T N

EP 120 / 200 T N

EP 120 / 100 T N

EP 80 / 100 T N

EP 40 / 120 T N

EP 40 / 100 T N

EP 40 / 60 T N

Dimensions (L x W x H)4

cm

361,8x113,8x219,1361,8x113,8x219,1361,8x113,8x219,1281,4x113,8x192,0281,4x113,8x192,0281,4x113,8x192,0281,4x113,8x192,0
Weight 4

kg

4400

4400

3850

3850

3850

3850

3650

ENERMAX-CUMMINS750 Ah1100 Ah4567
OPTIONS

Unit

EP 180 / 200 T N

EP 120 / 200 T N

EP 120 / 100 T N

EP 80 / 100 T N

EP 40 / 120 T N

EP 40 / 100 T N

EP 40 / 60 T N

Inlet Powerlocks

on request

on request

on request

on request

on request

on request

on request

Sockets

on request

on request

on request

on request

on request

on request

on request

Air Conditioning System

on request

on request

on request

on request

on request

on request

on request

Fire Extinguishing System

-

-

-

-

-

-

-

Solar Battery Charger

on request

on request

on request

on request

on request

on request

on request

Air filtration panels

on request

on request

on request

on request

on request

on request

on request

EV Charger DC CCS2

on request

on request

on request

on request

on request

on request

on request

EV Charger AC Type2

on request

on request

on request

on request

on request

on request

on request

1Up to SOC of 50%
2For temperatures > 45 °C Air Conditioning System is available as option

3With reduced DOD
4Dimensions may vary depending on the options added

Technical data not binding

LiFePO4 BATTERY CHEMISTRY

ENERMAX-CUMMINS234567

GENERAL TECNICAL DATA

Units

EP 180 / 200 T L

EP 120 / 200 T L

EP 120 / 100 T L

EP 80 / 100 T L

EP 40 / 120 T L

EP 40 / 100 T L

EP 40 / 60 T L

Three phase Voltage

VAC

400

400

400

400

400

400

400

Single phase Voltage

VAC

230

230

230

230

230

230

230

Frequency

Hz

50

50

50

50

50

50

50

Nominal Energy Storage

kWh

194

194

129

129

129

129

64

Continous load at power factor = 0,8

kVA

180

120

120

80

40

40

40

Overload (300 seconds)1

kV

350

350

350

350

350

350

350

Comunication technology

CAN bus

CAN bus

CAN bus

CAN bus

CAN bus

CAN bus

CAN bus

Sound Power Level

dB(A)

< 55 dB(A)@7m

< 55 dB(A)@7m

< 55 dB(A)@7m

< 55 dB(A)@7m

< 55 dB(A)@7m

< 55 dB(A)@7m

< 55 dB(A)@7m

Protection degree

IP44

IP44

IP44

IP44

IP44

IP44

IP44

Phases

3 PHASE

3 PHASE

3 PHASE

3 PHASE

3 PHASE

3 PHASE

3 PHASE

Operation Temperature

°C

-20 °C to +45 °C 2

-20 °C to +45 °C 2

-20 °C to +45 °C 2

-20 °C to +45 °C 2

-20 °C to +45 °C 2

-20 °C to +45 °C 2

-20 °C to +45 °C 2

ENERMAX-CUMMINS750 Ah1100 Ah4567
BATTERY

Unit

EP 180 / 200 T L

EP 120 / 200 T L

EP 120 / 100 T L

EP 80 / 100 T L

EP 40 / 120 T L

EP 40 / 100 T L

EP 40 / 60 T L

Brand

Quantity

units

12

12

8

8

8

8

4

Battery Voltage

VDC

179,2

179,2

179,2

179,2

179,2

179,2

179,2

Operating Voltage

VDC

716,8

716,8

716,8

716,8

716,8

716,8

716,8

Lithium cell chemistry

LiFePO4

LiFePO4

LiFePO4

LiFePO4

LiFePO4

LiFePO4

LiFePO4

Discharge current

1 C

1 C

1 C

1 C

1 C

1 C

1 C

DOD % (depth of discharge @25 °C ±3)

80%

80%

80%

80%

80%

80%

80%

Cycle Life3

>6000

>6000

>6000

>6000

>6000

>6000

>6000

Manufacturing Country

ITALY

ITALY

ITALY

ITALY

ITALY

ITALY

ITALY

ENERMAX-CUMMINS234567
INVERTER

Units

EP 180 / 200 T L

EP 120 / 200 T L

EP 120 / 100 T L

EP 80 / 100 T L

EP 40 / 120 T L

EP 40 / 100 T L

EP 40 / 60 T L

Brand

Quantity

units

1

1

1

1

1

1

1

Continuos load at power factor = 0,8

kVA

180

120

120

80

40

40

40

Nominal Power

kW

144

96

96

64

32

32

32

Accepted peak load @ 400V (300 sec)

kW

350 (2,43 Pn)

350 (3,64 Pn)

150 (1,56 Pn)

150 (2,34Pn)

150 (4,68Pn)

150 (4,68Pn)

150 (4,68Pn)

Manufacturing Country

ITALY

ITALY

ITALY

ITALY

ITALY

ITALY

ITALY

ENERMAX-CUMMINS750 Ah1100 Ah4567
CONTROL

Units

EP 180 / 200 T L

EP 120 / 200 T L

EP 120 / 100 T L

EP 80 / 100 T L

EP 40 / 120 T L

EP 40 / 100 T L

EP 40 / 60 T L

Energy Management system (EMS)

ComAp

ComAp

ComAp

ComAp

ComAp

ComAp

ComAp

Battery management system (BMS)

Hermes M3

Hermes M3

Hermes M3

Hermes M3

Hermes M3

Hermes M3

Hermes M3

Brand

Manufacturing Country

ITALY

ITALY

ITALY

ITALY

ITALY

ITALY

ITALY

ENERMAX-CUMMINS750 Ah1100 Ah4567
DIMENSIONS AND WEIGHT

Unit

EP 180 / 200 T L

EP 120 / 200 T L

EP 120 / 100 T L

EP 80 / 100 T L

EP 40 / 120 T L

EP 40 / 100 T L

EP 40 / 60 T L

Dimensions (L x W x H)4

cm

361,8x113,8x219,1361,8x113,8x219,1361,8x113,8x219,1281,4x113,8x192,0281,4x113,8x192,0281,4x113,8x192,0281,4x113,8x192,0
Weight 4

kg

4616

4616

4304

4304

4304

4304

3722

ENERMAX-CUMMINS750 Ah1100 Ah4567
OPTIONS

Unit

EP 180 / 200 T L

EP 120 / 200 T L

EP 120 / 100 T L

EP 80 / 100 T L

EP 40 / 120 T L

EP 40 / 100 T L

EP 40 / 60 T L

Inlet Powerlocks

on request

on request

on request

on request

on request

on request

on request

Sockets

on request

on request

on request

on request

on request

on request

on request

Air Conditioning System

on request

on request

on request

on request

on request

on request

on request

Fire Extinguishing System

-

-

-

-

-

-

-

Solar Battery Charger

on request

on request

on request

on request

on request

on request

on request

Air filtration panels

on request

on request

on request

on request

on request

on request

on request

EV Charger DC CCS2

on request

on request

on request

on request

on request

on request

on request

EV Charger AC Type2

on request

on request

on request

on request

on request

on request

on request

1Up to SOC of 50%
2For temperatures > 45 °C Air Conditioning System is available as option

3With reduced DOD
4Dimensions may vary depending on the options added

Technical data not binding